Heltec Automation

Establishing connection

HELTEC image
HELTEC KNOWLEDGE NETWORK / FAQ DETAIL
Q

## What are the requirements for SDIO host?

Public FAQ1 response1 from Heltec team
01 / RESPONSE STREAM

Answers & Discussion

01 ENTRIES

Follow the conversation from the Heltec team and the community.

  1. Heltec teamOFFICIAL RESPONSE

    1. The host should support SDIO v2.0 with SDIO clock speeds of up to 50 MHz. Slower clock speeds will impact the maximum achievable throughput. 1. At a minimum, 2 x GPIOs are required as a CMOS output to drive the RESET and WAKE signals. If power save is used, a third GPIO is needed, set as a CMOS input to receive the BUSY signal from the module. 1. The SDIO data and command lines should be pulled up with 10k-100k resistors as per the SDIO 2.0 specification.